0011
Alarm 0011 (Axis selection error) Diagnostic Tree
Interactive troubleshooter
Step 1 of 3Check the rotary switch settings on the drive unit. Ensure that the switch for each drive (from 0 to F) is set correctly and uniquely according to the axis order in the system.
↺ Restart from step 1All diagnostic steps
STEP 1
Check the rotary switch settings on the drive unit. Ensure that the switch for each drive (from 0 to F) is set correctly and uniquely according to the axis order in the system.
STEP 2
Check the axis and spindle parameters. Ensure there are no skipped channel numbers or duplicate settings in the parameters #1021 (mcp_no) and #3031 (smcp_no).
STEP 3
Check if the axis has been disabled accidentally. Inspect whether the parameters #8201 (Ax. Release) and #1070 (axoff) are unintentionally set to '1' (disabled).